Skip to content
Krepšelis



Viso
Eiti į krepšelį
Grotelės DEMCiflex, balta | Kompiuterinė technika, biuro prekės | Https://senukai-lt-web-test.ksd.zone | 0
Grotelės DEMCiflex, balta | Kompiuterinė technika, biuro prekės | Https://senukai-lt-web-test.ksd.zone | 1

Grotelės DEMCiflex, balta


brand-logo


Išparduota

Prekė šiuo metu yra išparduota

Prekės informacija

Bendrosios charakteristikos

  • Prekės ženklas

  • Spalva

    Balta

  • Papildoma informacija

    Matmenys (rėmas): Ø 110 mm. Matmenys (filtras): Ø 85 mm. Suderinamumas: 92 mm ventiliatoriaus jungtis. Medžiaga (filtras): poliesterio tinklelis. Spalva: balta (rėmas), balta (filtras). Tvirtinimas: magnetinis tvirtinimas + montavimo rėmas. Ypatybės: Greitas sumontavimas. Nevaržo jungčių

Prekės atspalvis gali skirtis nuo matomo nuotraukoje.

Prekės aprašymas anglų kalba:

If you open your PC again after half a year, perhaps to install new hardware, one wonders most of the time whether the Rechenknecht is not better to call a vacuum cleaner. What makes it easier on the one hand - imagine just how much more often the room would have to be cleaned if all the dirt was not collected as a precaution by the computer - means elsewhere consuming cleaning of the PC interior.

In addition, dust in the housing is the main reason for overheating and thus for possible, unstable operation. Although a cleaning time-to-time can not be prevented, however, the effort can be significantly reduced. A simple and cost-effective solution are dust filters, which are placed in front of the sucking fans. Once installed, it is no longer necessary to dedust the entire interior with all its inaccessible corners and sensitive components, only the filters.

DEMCiflex offers a particularly easy-to-retrofit solution. Here, the filter is simply placed from the outside of the housing on the fan opening and is held there magnetically. There are therefore no screws or the like necessary, so there is no compatibility restriction. Since not all fan positions are magnetically attractive, an additional frame to the scope of delivery is glued to the back and on which the filter is held.

The filter itself consists of a very tightly woven and durable polyester fabric. This special material is also used in clinics, for example to keep operating theaters dust-free. At the same time, the net is well permeable to air and therefore hinders the airflow only slightly.

Of course, this effect diminishes with increasing dust, which is why the filter should occasionally be removed and cleaned. This is very simple in many ways. Due to the special mounting method, the removal of the fan is again very easy and fast. Afterwards, the dust can either be brushed, shaken, washed off and even scraped off with stubborn dirt.

Finally, a few notes on the installation: First, the question arises, which fans have to be covered at all. As already mentioned, this applies exclusively to the sucking fans. But which are they?

The safest way to recognize this is on the fan itself, with two arrows on the outside or inside of the fan frame. If one of the two arrows points towards the interior or if the rotor suspension is aligned with the interior, this is an aspirating fan. These are usually located on the front, side and bottom, whereas the rear and cover fans usually carry the air out of the housing and therefore need not be filtered.

In order to maximize the filter effect, an overpressure in the housing can be generated. This means that more volume of air is forced into the housing than is being sucked out of the housing by other fans at the same time. This prevents air (and with it the dust) from entering the interior through other openings that may not have been filtered.

If all fans are the same size, you should blow more fans into the housing than pull out. In this case, the power supply is to be counted as an additional, extracting fan, as long as it does not receive its supply (fan side) directly from the outside (occurs at floor mounting). If different fans with different sizes and speeds are used, the respective air volumes (m³ / h) in the data sheets give a good reference value, whereby in turn the total volume of the suction fans must be higher than that of the blowing out fans.

Note: The area around the used fan slot should be flat if possible and have no protruding parts. Otherwise, these may impair adhesion to the substrate.

Dažnai perkama kartu

Paštomatu 0€

Adapteris Logilink, sidabro

Adapteris Logilink, sidabro

Įprasta kaina

37,90 €

Paštomatu 0€

Smart leasing 9

Maitinimo blokas be quiet! Straight Power 11 750 W, 13.5 cm

Paštomatu 0€

Smart leasing 9

Maitinimo blokas Fortron FSP 300-50AHBCC 300 W

Maitinimo blokas Fortron FSP 300-50AHBCC 300 W

399,00 €

Įprasta kaina

429,00 €

Smart leasing 9

Kompiuterio korpusas Corsair, juoda

Kompiuterio korpusas Corsair, juoda

Įprasta kaina

201,90 €

Paštomatu 0€

Smart leasing 9

Kompiuterio korpusas Antec, juoda/raudona

Paštomatu 0€

Smart leasing 9

Kompiuterio korpusas SilverStone, juoda

Paštomatu 0€

Skysčio aušinimo sistemos priedas, adapteriai Corsair iCUE LINK GPU RGB, 18 g, juoda

Paštomatu 0€

Smart leasing 9

Maitinimo blokas ASRock Steel Legend SL-1000G 1000 W, 13.5 cm, 1 - 25 dB

Smart leasing 9

Kietasis diskas Lexar, SSD, 4 TB, juoda

Smart leasing 9

Išorinis diskas Lexar SL300, SSD, 2 TB, juoda

Smart leasing 9

Atminties kortelė Cisco, 4 GB

Atminties kortelė Cisco, 4 GB

349,00 €

Įprasta kaina

369,00 €

Paštomatu 0€

Smart leasing 9

Maitinimo blokas Gigabyte Aorus AE1000PM PG5 Ice 1000 W, 12 cm

Atsiliepimai

Neseniai peržiūrėjai